The tBeacon Amber radio detection board is the evolution of the legendary series with intelligent power management!
The tBeacon Amber modification is a deep engineering upgrade of the popular Green series board, which has received a radical update of the circuitry and a fully automated power management system. The main feature of this lightweight model is intelligent protection circuits of switching interfaces and a complete rejection of outdated mechanical toggle switches in favor of a reliable vibration-resistant clock button.
This makes the tBeacon Amber electronic board an ideal and uncompromising choice for professional integration on board modern civil multicopters, aircraft and heavy agricultural drones. The module works in conjunction with an external GPS chip and guarantees 100% survivability of the search circuit and stable transmission of geocoordinates directly to your Baofeng radio even with a complete power outage on board!
Recommended tBeacon Target Starter Kit with Accessories
Detailed technical review and innovative functionality of the tBeacon Amber radio detection board
The tBeacon Amber search and rescue beacon is an evolution of the legend with intelligent power management! This modification is an improved engineering version of the popular Green series beacon, which has received a radical update and a deep modernization of the power supply system.
The main feature of the Amber board is the full automation of the wireless circuit and the implementation of intelligent protective circuits, which makes this emergency beacon an ideal choice for professional integration into the power networks of modern civilian multicopters, aircraft models, and heavy agricultural drones.
Key engineering innovations of the Amber version:
- Smart Circuit Activation Mode: The autonomous beacon turns on fully automatically when your model or agricultural drone’s onboard network is started. The operator no longer needs to worry about manually turning on the system before takeoff.
- Reliable external circuit protection: Special protection circuits have been incorporated into the PCB layout to safeguard against incorrect connection of the module to the vehicle’s power system or an external GPS module.
(⚠️ Important engineering note: This protection applies only to external connection interfaces. There is no reverse-polarity protection on the input lines for the standalone battery itself, so strictly observe polarity when soldering!) - Electronic smart power management: The outdated mechanical switch of the Green series has been replaced by a reliable pulse power button, which significantly increases the overall vibration resistance of the module under flight loads.
Contents of the engineering delivery kit for Amber series modules:
Each radio detection board undergoes mandatory pre-sales technical training (it is shipped to the user in a “Ready-to-Test” state – fully flashed with the most up-to-date software and hardware calibrated).
The standard delivery includes:
- tBeacon Amber radio tracking PCB with a wire antenna;
- Special switching cable for quick engineering integration of the board with an external GPS module and an on-board 5V power line;
- Reinforced autonomous Li-Po battery with a capacity of 180 mAh;
- Information accompanying insert with service QR code;
- Branded sticker-brand logo.
⚠️ Important engineering requirement: To ensure absolute vibration resistance of the wireless circuit and protection against contact separation during flight loads, the battery terminals must be soldered to the factory pads on the board before the system is put into operation.
*The manufacturer reserves the right to adjust the nominal capacity of the autonomous battery according to the current availability of batteries in the production warehouse. The total autonomous operation time of the search beacon is guaranteed to remain within the factory standard (up to 7 days in standby mode).
Functional and search potential of the wireless system:
- Voice Telemetry Over the Air: Receive accurate GPS satellite coordinates and up-to-date data on the current voltage of the model’s main running battery (power packs up to and including 6S Li-Po are supported) by voice directly to your standard VHF radio.
- Proximity Mode (Digital Radio Direction Finding): A unique algorithm for finding an object by direction finding based on signal strength in areas where the GPS satellite signal is completely absent or blocked.
- Remote activation by call: The ability to contactlessly trigger the emergency beacon transmitter directly from the radio or according to a pre-set internal safety timer.
- Light-sound search complex: A high-power LED beacon and a loud sound siren (buzzer) are installed on board the printed circuit board for quick visual and acoustic location of the object in difficult conditions (dense tall grass, snow, bushes).
Ultimate compactness without compromise:
- Ultra-lightweight engineering: The entire design weighs only 5–6 grams with the included 180mAh battery attached! The board does not disturb the alignment at all.
- Subminiature dimensions: The compact hardware form factor (only 20×30 mm) allows you to easily place the radio beacon even in the tightest and most limited space of the internal compartment.
- Record autonomy: Up to 7 days of continuous operation in standby mode from its own backup battery.
CLICK HERE FOR ROSKRITI REVIEW DESCRIPTION
Technical regulations for commissioning, commissioning and installation rules:
⚠️ Important note for professional developers and engineers:
Please note that the tBeacon Amber radio detection board is supplied in the format of a specialized kit (semi-finished product) for professional installation and self-commissioning. In order to achieve absolute fault tolerance, the module architecture is completely devoid of unreliable mechanical switches or power connectors that can break off or open from strong flight vibrations of the agricultural drone.
The backup battery is supplied separately. Before starting operation and integration into the board, the engineer must independently solder the battery terminals to the corresponding factory contact pads on the search beacon printed circuit board. This manipulation ensures maximum monolithicity of the communication node, but requires basic skills in working with soldering equipment.
Engineering innovations and architectural differences of the Amber series:
The Amber model is an intelligent evolutionary development of the tBeacon radio detection line, where every detail is aimed at absolute autonomy and safety of the location circuit. Thanks to the complete rejection of the mechanical switch in favor of a tact button, the electronic module has become even more compact and reliable in the most difficult operating conditions.
- Smart intelligent start: The emergency beacon is activated automatically when charging voltage appears from the general on-board network or when “phantom” power appears on the signal lines of the connected external GPS module.
- Built-in hardware protection system: Special protective circuits against erroneous or mirrored connection of interface lines are implemented in the PCB topology, which fully guarantees the safety of expensive electronics during deep installation.
- Electronic control: Instead of outdated mechanical toggle switches, the board is equipped with a reliable service power button with a high resource of presses.
Full wireless control, radio direction finding and search algorithms:
- Voice Telemetry Broadcast: The tBeacon Amber autonomous beacon dictates current GPS/GNSS satellite coordinates and reports the voltage level of the power battery (2S to 6S Li-Po assemblies are supported) in a clear human voice directly to your VHF radio.
- Combined final location complex: Synchronous use of the proprietary Proximity radio direction finding mode together with a super-loud built-in buzzer (siren) and a bright LED guarantees 100% success in finding the object by the operator even in thick tall grass, bushes or deep snow.
- Remote contactless activation: Calling and forced polling of the emergency beacon transmitter is carried out natively with the help of a walkie-talkie or with a pre-configured internal service safety timer.
- Direct configuration via PC: All service settings and precise calibration of the frequency loop are performed via the official “Configurator” application for PC using a direct connection via a micro-USB data cable.
tBeacon Amber service, preparation and commissioning:
The Amber modification is designed for professional use and requires a qualified engineering approach to installation. Strict adherence to the recommendations of the official technical regulations below will ensure uninterrupted operation of the emergency beacon and guaranteed location of the object even after extremely hard landings of the agricultural drone or prolonged exposure to an aggressive humid environment.
Protection, waterproofing and sealing rules for printed circuit boards:
To ensure uninterrupted and stable operation of the wireless circuit in extreme field conditions (high humidity, condensation, snow, fog), it is necessary to carry out initial engineering preparation of the board:
- Radio-technical insulation: Evenly coat the printed circuit board with specialized dielectric varnish or “liquid insulating tape.”
- Physical battery installation: Only after the dielectric varnish has completely dried, carefully solder the battery terminals to the corresponding factory contact pads on the printed circuit board.
- Final heat shrink: Place the self-contained beacon with the connected battery in a protective heat shrink tube and gently heat it with a hair dryer to fully fix the shell and protect the elements from mechanical damage.
⚠️ Important technological warning: When applying the protective coating, strictly avoid getting insulating varnish inside the interface connector, on the contact lines of the clock service control button, and in the acoustic hole of the sound buzzer (siren) of the emergency beacon.
⚠️ Critical engineering safety rules (Must read before commissioning!):
- Uncompromising polarity: Strictly observe the polarity when connecting and self-soldering the battery! The ultra-light Amber modification, due to strict weight savings, does NOT have built-in hardware protection against reverse polarity at the battery power input. The negative contact (ground line, black wire) is located closer to the physical edge of the printed circuit board. An error during soldering will lead to instant burnout of the microcircuits!
- Strict thermal regime: Completely avoid overheating the lithium-polymer (Li-Po) battery when soldering contacts or fixing heat shrink, especially if the battery is in a fully charged state.
- Antistatic tools: Use only specialized dielectric or antistatic tools for any service manipulations with a radio detection board to which an autonomous battery is already connected (soldered). Avoid accidental contact of exposed circuit boards with metal objects, screwdrivers, or fasteners to prevent critical short circuits (short circuits).
Installation and spatial mounting recommendations for civil platforms:
- Mechanical protection: It is strictly forbidden to install the search beacon board in places and technological compartments of the frame where it can be accidentally crushed, squeezed or damaged by heavy structural elements (for example, a massive main power battery) in the event of a hard landing or emergency collision of the agricultural drone.
- Radio transparency and antenna sensitivity: To ensure maximum wireless range, avoid placing the emergency beacon board under solid metal or carbon (carbon) fuselage parts that can completely shield the radio signal and block the operation of the built-in GPS/GNSS chip.
- Removing the external service button: If the printed circuit board is installed deep inside the closed housing of a civil aircraft model, bring the additional duplicate power button outside (the corresponding engineering output is located below the main interface connector, system activation is implemented by closing the line to ground GND).
Power management algorithms, power on and power off:
The Amber electronic radio detection module is equipped with an automated engineering power management system that supports two independent activation modes:
- Manual start: This is done by briefly pressing (0.5 sec) the service pulse button on the printed circuit board. The search beacon will confirm readiness with a light indication, a sound signal (starting melody) and an automatic voice message on the air about the current voltage of its own backup battery.
- Smart-start mode (Automatic start): The board is activated independently when a DC 5V supply voltage (DC +5V) appears on the corresponding contact of the interface connector or when “phantom” power appears on the signal lines of communication with an external GPS module (UART RX/TX lines). This is an ideal solution for full automation of aboard a civil aircraft model or agricultural drone.
- Smart-start mode (Automatic start): The board is activated independently when a DC 5V supply voltage (DC +5V) appears on the corresponding contact of the interface connector or when “phantom” power appears on the signal lines of communication with an external GPS module (UART RX/TX lines). This is an ideal solution for full automation of aboard a civil aircraft model or agricultural drone.
To completely shut down or force the system to reboot (Reset) in critical situations, you must hold the power button down for at least 5 seconds.
Amber intelligent power control, protection and monitoring system:
The tBeacon Amber modification is equipped with an advanced engineering system for voltage analysis and measurement. It allows the pilot to receive live telemetry of both the board’s own backup power supply and the real state of the model’s power battery (full support and monitoring of running batteries from 2S to 6S Li-Po inclusive).
The emergency beacon safety circuits prevent critical and deep discharge of the lithium cell:
- Automatic start-up lock: If the voltage of the own backup battery drops below the critical level of 3.0V, the launch of the beacon transmitter is automatically blocked by the control board to protect the chemical structure of the Li-Po cell.
- “Delayed start” mode: The electronic module goes into a safe energy level standby mode (informing the operator with specific red LED flashes) until the voltage on the power lines rises to a safe engineering level of 3.3V.
- Voice report on voltage: At each successful start, the radio beacon dictates the current voltage of its own battery in a clear human voice to the Baofeng walkie-talkie (for example, the phrase “three eight” generated by the board means the exact level is 3.8V).
Intelligent monitoring of the model’s running battery (Vext Function):
If the engineering function “External battery thresholds” is activated, the tBeacon Amber standalone board turns into a full-fledged interference-resistant flight telemetry sensor that monitors the state of the power circuit:
- Automatic configuration detection: When started, the emergency beacon automatically determines the number of cells in the common running battery and confirms successful detection with tone signals (for example, three clear “beeps” signal the connection of a 3S Li-Po assembly).
- Voice notification about voltage: The Beacon broadcasts the average voltage calculated for each individual power bank (the phrase “four two” generated by the board means the exact level of 4.2V per cell).
Adaptive operator notification service modes:
- “Warning” mode: When the first configured safety threshold is reached, the current running battery voltage is automatically reported by voice over the air of the Baofeng radio every 15 seconds.
- “Critical Level” mode: When the voltage drops to the critical lower limit, the emergency beacon board begins to dictate data to the air every second and forcibly turns on the light-sound siren (buzzer).
- Automatic Sleep Mode (Protection): If the board voltage drops below 2.5V per bank, the intelligent system considers the battery to be completely disconnected and automatically puts the board into sleep mode after the final beep.
- Recommended factory configurator setting: Engineering value “3533” (warning is activated at 3.5V, critical level – at 3.3V per Li-Po bank).
Connection interfaces, connector pinout and service configuration of tBeacon Amber:
The Amber modification is designed for deep integration on board civil aircraft, multicopters and heavy agricultural drones. For maximum convenience of installation, commissioning and programming, the printed circuit board is equipped with a universal 5-pin interface connector (a proprietary plug and contacts for crimping or soldering are already included in our basic engineering delivery kit).
Pinout of the Amber board interface connector (GND, +5V, UART, Vext):
(Below is a detailed diagram of the cable lines and switching of the electronic module with an external GPS chip and the power circuits of the agrodrone’s running battery).

| Contact | Appointment | Functional description |
| Vext | Battery monitoring | Input for monitoring the power battery (connected to “+”). |
| RX | UART input | Receiving GPS data or connecting to a PC (Data Input). |
| TX | UART output | Data transfer to PC (Data Output). |
| +5V | Power / Charging | Input voltage 5V for charging the built-in battery. |
| GND | Total (Minus) | Common ground bus for all lines. |
| EXT_BUTTON | External button | Output for remote control button (shorted to GND). |
Software configuration, calibration and firmware update:
The Amber series radio-identification board supports flexible configuration of operating parameters, service timers, and security settings. To interface with the official “Configurator” utility on a PC, use a standard external USB-UART adapter.
⚠️ Important engineering rule for data line switching:
When connecting, strictly observe the polarity and digital stream redirection scheme: the RX information output of the emergency beacon is connected to the TX output of the external UART adapter (classic crossed wireless connection of data lines).
Engineering algorithms for connecting the board to the “Configurator” program (2 available methods):
Hot Plug Mode: If the emergency beacon is already powered on and working at the time of setup, press and hold its service button on the PCB for 5 seconds. Then press the CONNECT button in the PC application interface and gently release the button on the beacon board.
Cold Start Mode: Press the CONNECT service button in the PC program interface and immediately connect the patch cable to the completely turned off search beacon. The board will automatically activate and connect.